Sync Setup - Pro Tools on a separate computer via network MTC, MMC & HUI
Introduction
The easiest way to provide Video Sync with incoming MTC/MMC data from another computer, is to setup a network MIDI connection using Apple's built-in Audio MIDI Setup tool to transmit all the MIDI data between the two computers. It is usually not necessary to buy a separate MIDI interface and cables to connect the MTC sending and receiving computers, although a cabled MIDI connection can be used if preferable. Since MIDI was developed in the 80s, it has a really low data rate. Therefore it should not be a problem to use network MIDI in a Wi-Fi environment.
A cabled ethernet network connection is the preferred method for reliability.
The following instructions assume that you have two Apple Macs: one with Video Sync; the other with Pro Tools®.
Although not listed as a separate DAW Sync Setup Option, this Network MIDI setup incidentally also works flawlessly with Video Sync on the same computer.
If the Pro Tools® computer is a PC, rtpMIDI is a free PC equivalent to Apple's network MIDI implementation. Download & setup instructions can be found here: http://www.tobias-erichsen.de/software/rtpmidi.html
Our thanks to Tobias Erichsen for this invaluable tool.
{width=80%}
Configuring Audio MIDI Setup on the Pro Tools® computer to send MTC & MMC over the Network
On the Pro Tools® computer, go to Applications > Utilities & open Audio MIDI Setup. The MIDI Network Setup window should appear:
{width=80%}
If the window is not shown, select Window > Show MIDI Studio & then from the MIDI Studio menu that appears, select Open MIDI Network Setup.
In newer versions of macOS, the Open MIDI Network Setup option is accessed via the Network Icon to the top right of the window, called Configure Network Driver.
{width=80%}
In older versions of Audio MIDI Setup where this option is not present, it can accessed by double-clicking the Network device icon in the default MIDI Studio window.
{width=80%}
In the My Sessions field top left, create a new session by clicking +.
Click the checkbox to the left of the name to enable the session.
Rename it (computer 1 name) MTC/MMC Send (or something similar) - e.g. MacProHDX MTC/MMC Send This name will automatically be copied to the Local name field.
The Local name is the name that appears on this local computer.
Copy this name & paste it in the Bonjour name field.
The Bonjour name is the name that is displayed on the other computers in the network.
Although a session can be used in either input or output directions, to avoid confusion it is recommended to stick to one direction by noting this in the session name, e.g. Send or Out.
MTC & MMC do not require separate Network sessions made for each - they can share the same session.
Set the Port: field to 5004.
If this Port has already been assigned a different number - especially where other sessions already exist that may be using 5004, it is advised to use this suggested unique new number. Assign a unqiue number for each session - with prefereably at least one free number between each assigned port.
Select Anyone in the Who may connect to me dropbox on the bottom left.
{width=80%}
Configuration is complete for the Pro Tools® computer. This should not need to be set up again in future.
Configuring Audio MIDI Setup on the Video Sync computer to receive Network MTC & MMC
On the Video Sync computer, close Video Sync & open Audio MIDI Setup. Open the MIDI Network Setup window as described above. The Pro Tools® computer should be visible in the Directory field - showing (computer 1 name) MTC/MMC Send with a green active circle to the left.
{width=80%}
In the My Sessions field top left, create a new session by clicking +.
Click the checkbox to the left of the name to enable the session.
Rename it (computer 2 name) MTC/MMC Receive (or something very similar)- eg MacbookPro MTC/MMC Receive.
This name will automatically be copied to the Local name field.
Copy this name & paste it in the Bonjour name field.
Set the Port: field to 5006.
Select Anyone in the Who may connect to me: selection field on the bottom left.
{width=80%}
Connecting the Network MTC/MMC Sessions
Now that the two Sessions have been created, the next step is to connect them.
The steps until this point should not need to be done again in future. The following simple steps to connect only need to be done once every time the computers are restarted.
With the (computer 2 name) MTC/MMC Receive session selected in the My Sessions box, select (computer 1 name) MTC/MMC Send in the Directory field, and hit the Connect button.
(computer 1 name) MTC/MMC Send should now appear in the Participants: field on the right.
{width=80%}
Regardless of which computer is chosen to Connect, only one of the computers needs to connect to establish the connection.
On the Pro Tools® computer, (computer 2 name) MTC/MMC Receive should now also be seen in the Participants: window.
{width=80%}
If the (computer 2 name) MTC/MMC Receive session does not show up in the Directory list, try re-launch Audio-MIDI-Setup.
Video Sync MTC / MMC Setup
Launch Video Sync.
If Video Sync was open already, use the "Rescan Available MIDI Ports" button in the SYNC preferences.
To show the MIDI I/O options in Video Sync, first navigate to the SYNC tab of the Preferences window.
Set the Sync Source field to Pro Tools.
Set the Sync Method field to MIDI.
Next, select Network (computer 2 name) MTC/MMC Receive in both the MTC In & MMC In fields, as per the image below:.
{width=70%}
Pro Tools Network MTC (MIDI Timecode) Setup
In Pro Tools®, go to Setup > MIDI > MIDI Input Devices & make sure that the Network, (computer 1 name) MTC/MMC Send is enabled.
{width=50%}
MIDI Inputs are disabled by Pro Tools® by default until they are manually activated.
Next go to Setup > Peripherals > Synchronization tab.
In the MTC Generator Port dropdown menu, choose Predefined > Network, (computer 1 name) MTC/MMC Send.
Click OK to close the window.
Check that the expanded Synchronization box is showing in the Transport Bar (or Transport Window), by clicking on the top right arrow, & making sure the Synchronization tab is selected.
Hit the GEN MTC button.
{width=70%}
Pro Tools Network MMC (MIDI Machine Control) Setup
To enable MMC in Pro Tools®, go to the Machine Control tab of the Setups > Peripherals window.
In the Machine Control Master field, set the Enable checkbox.
Check that the ID field is set to 127.
Select Predefined > Network, (computer 1 name) MTC/MMC Send.
Click OK to close the window.
Now go to Setup > Preferences > Synchronization tab.
Make sure that Machine Chases Memory Location and Machine Follows Edit Insertion/Scrub are both enabled:
When Machine Chases Memory Location is enabled, Pro Tools® will send an MMC Locate command whenever a specific memory location is clicked. With the Machine Follows Edit Insertion/Scrub checkbox checked, Pro Tools® will send MMC Locate commands every time the position of the edit insertion is changed.
Configuring Audio MIDI Setup on the Video Sync computer to send and receive HUI
If looped playback is required with MTC & MMC sync options, Video Sync must be enabled as a HUI controller.
If looped playback is not required, for best performance it is suggested to leave HUI off - in which case this step can be skipped until the Enabling Synchronised playback section of this chapter.
Unlike MTC & MMC, HUI controllers need a two-way connection - meaning that they send and receive information. One session in Audio MIDI Setup can receive and transmit HUI information at the same time though - so there's no need to create separate sessions to send and receive HUI messages.
On the Video Sync computer, go to Applications > Utilities & open Audio MIDI Setup again.
{width=80%}
In the My Sessions field top left, create a new session by clicking the +.
Click the checkbox to the left of the name to enable the session.
Rename it (computer 2 name) HUI (or something very similar) - e.g. MacbookPro HUI.
This name will automatically be copied to the Local name field.
Copy this name & paste it in the Bonjour name field.
Set the Port: field to 5006.
Select Anyone in the Who may connect to me: selection field on the bottom left.
Video Sync Network HUI Setup
Open the SYNC tab in the Preferences window.
Select the newly created HUI session Network (computer 2) HUI for HUI In.
Select the newly created HUI session Network (computer 2) HUI for HUI Out.
Configuring Audio MIDI Setup on the Pro Tools computer to send and receive HUI
Switch to the Pro Tools® computer & open Audio-MIDI Setup.
The Video Sync computer's HUI session should be visible in the Directory field - showing (computer 1 name) HUI with a green active circle to the left.
In the My Sessions field top left, create a session by clicking +.
Click the checkbox to the left of the name to enable the session.
Rename it (computer 1 name) HUI (or something very similar) - e.g. MacProHDX HUI.
This name will automatically be copied to the Local name field.
Copy this name & paste it in the Bonjour name field.
Set the Port: field to 5006.
Select Anyone in the Who may connect to me: selection field on the bottom left.
Connecting the Network HUI Sessions
Still in Audio MIDI Setup on the Pro Tools computer, with the (computer 1 name) HUI session selected in the My Sessions box, select (computer 2 name) HUI in the Directory field, and hit the Connect button.
(computer 2 name) HUI should now appear in the Participants: field on the right.
{width=80%}
Pro Tools Network HUI Setup
In Pro Tools®, go to Setup > MIDI > MIDI Input Devices & make sure that the Network, (computer 1 name) HUI is enabled.
{width=50%}
Next go to Setup > Peripherals > MIDI Controllers tab.
In the first row, under the Type column, select HUI.
In the adjacent Receive From column, select Network, (computer 1 name) HUI.
In the adjacent Send To column, select Network, (computer 1 name) HUI.
Only one HUI bank is required for loop playback. But more can be added for DAW Control.
Click OK once done. Pro Tools® will start sending HUI messages to Video Sync periodically to check if the HUI controller is still connected. Video Sync will reply to these messages by sending a MIDI message back. Open Audio MIDI Setup's MIDI Network Setup** again. This MIDI traffic (depicted by tiny red lines) should be visible when selecting the HUI port on either computer.
{width=80%}
If these lines are visible, ADR Master is successfully connected as HUI controller to Pro Tools®. ADR Master will now be able to properly follow loops set in Pro Tools®.
Although Video Sync can follow loops in Pro Tools®, it is possible that playback can drift out of sync slightly after a few iterations of the loop when using HUI.
Enabling Synchronised playback
When hitting play or scrubbing within Pro Tools®, both the incoming timecode field should now be seen incrementing & the timecode rate displayed within the Incoming TC section to the left of the main timecode counter in Video Sync.
{width=70%}
If the Sync button to the left of the transport buttons isn't already blue, click on it to activate it to follow external sync.
{width=30%}
Video Sync MTC/MMC sync is now online & ready to go. Hit play in Pro Tools® and Video Sync will play back in sync.
Dealing with MTC sync with high frame rate content
Video Sync allows for synchronised playback of clips running at up to 60 frames per second. Being a standard from the 80s, MIDI timecode (MTC) does not support frame rates higher than 30 frames per second. To be able to play timelines with these high frame rate clips in sync to MTC, Video Sync will try to match the incoming TC at half the frame rate. For example, if the timeline has a 50fps clip, Video Sync will play it in sync if a 25fps MTC source is supplied.
In the timeline list, the timeline frame rate is shown here:
{width=60%}